Launch O2-2 Oscilliscope

R0.00 EX VAT

Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detect faults on various electrical components, such as sensors, actuators and circuits. By integrating with the X-431 series scan tools via the O2-2 application, it delivers accurate and conclusive diagnostic faults that enable the shop and technician to enlarge their scan tool’s functionality.


Brand:Launch

Description

See it in action … BOOK  DEMO

LAUNCH

O2-2 Oscilliscope

  • 4 Chanel Oscilloscope
  • 23 automotive measurement items
  • Add new waveforms for future reference
  • Test actuators, Ignition, Circuits and more

Functions:

  • Provides all kinds of testing applications on automotive parts (including circuits, sensors, actuators, ignition etc.).
  • Menu Includes the following options:
  • Measure: It provides 23 parametric measurement items.
  • Save: It allows you to save the current waveform as a reference waveform for future comparison.
  • Display: Sets the display mode of the waveform.
  • User Setting: The following items are available: storage depth, factory reset, self-adjust (self-calibration), and save & recovery.
  • About: Displays the detailed information of the app.

 

Features:

  • ECU troubleshooting and Diagnostics
  • Features the ability to record and playback high-resolution waveform data for future analysis.
  • a particular waveform which makes the process 70% more efficient as compared to other scopes
  • Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch
  • Ability to input names and characters directly by clicking on the virtual keyboard, this operation streamlines the process and contributes to 90% efficiency
  • Buffer memory up to 50M
  • Use the zoom in/out feature to review precise details
  • Customizable personal system settings that can be saved as configuration files for viewing
  • The Self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy
  • Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis
  • Multiple automotive tests that include circuits, sensors, actuators, ignition tests and more
  • Multi language user interface

USB Sunc data transfer to external devices such as laptop, tablet, etc..

Channels4
Bandwidth100MHz
Rising Time3.5ns (typical)
Accuracy±3%
Input Impedance1M ±1.5%
Input TypeSingle-ended, BNC Connector
Input CouplingDC, AC
Overload Protection±200V on single input
Timebase Ranges1ns~1ks (1 Channel)
1ns~1ks(2 Channels)
1ns~1ks(4 Channels)
Vertical Resolution8bits
Buffer Memory10M (for 4 Channels)
Power InterfaceUSB port, DC IN port
Data Exchange ViaUSB
Trigger ModeNormal, Auto and Single SEQ
Advanced TriggersEdge, Pulse width
Description

LAUNCH

O2-2 Oscilliscope

  • 4 Chanel Oscilloscope
  • 23 automotive measurement items
  • Add new waveforms for future reference
  • Test actuators, Ignition, Circuits and more

Functions:

  • Provides all kinds of testing applications on automotive parts (including circuits, sensors, actuators, ignition etc.).
  • Menu Includes the following options:
  • Measure: It provides 23 parametric measurement items.
  • Save: It allows you to save the current waveform as a reference waveform for future comparison.
  • Display: Sets the display mode of the waveform.
  • User Setting: The following items are available: storage depth, factory reset, self-adjust (self-calibration), and save & recovery.
  • About: Displays the detailed information of the app.

 

Features:

  • ECU troubleshooting and Diagnostics
  • Features the ability to record and playback high-resolution waveform data for future analysis.
  • a particular waveform which makes the process 70% more efficient as compared to other scopes
  • Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch
  • Ability to input names and characters directly by clicking on the virtual keyboard, this operation streamlines the process and contributes to 90% efficiency
  • Buffer memory up to 50M
  • Use the zoom in/out feature to review precise details
  • Customizable personal system settings that can be saved as configuration files for viewing
  • The Self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy
  • Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis
  • Multiple automotive tests that include circuits, sensors, actuators, ignition tests and more
  • Multi language user interface

USB Sunc data transfer to external devices such as laptop, tablet, etc..

Tech Specs
Channels4
Bandwidth100MHz
Rising Time3.5ns (typical)
Accuracy±3%
Input Impedance1M ±1.5%
Input TypeSingle-ended, BNC Connector
Input CouplingDC, AC
Overload Protection±200V on single input
Timebase Ranges1ns~1ks (1 Channel)
1ns~1ks(2 Channels)
1ns~1ks(4 Channels)
Vertical Resolution8bits
Buffer Memory10M (for 4 Channels)
Power InterfaceUSB port, DC IN port
Data Exchange ViaUSB
Trigger ModeNormal, Auto and Single SEQ
Advanced TriggersEdge, Pulse width
PDF

Are you making the correct equipment choice?

Speak to a real industry expert and get the correct advise on what tool will best suit your requirements. Make the right choice with no regrets.

CONTACT US